Heavy current dry type composite capacitive type wall bushings

Add time:2022-03-15 15:20:04   Number of views:88  

■ Product features
· Non-porcelain,non-gas,unfilled oil
· Fire proof,explosion proof
· Maintenance-free
· Smaller volume,lighter weight
· Ambient air temperature form -40 ℃ to +50℃

■ Technical parameters
· Highest voltage:12~40.5kV
· Rated current:100~5000A
· Rated frequency:50Hz、60Hz

■ Environment condition
· Installation way:indoor-indoor,outdoor-indoor or outdoor-outdoor,level installation or vertical installation.
· Ambient air temperature:-40~+50℃
· Altitude:1000m(confering with consumer if above 1000m)
· Pollution class:Ⅱ、Ⅲ、Ⅳ

■ Main performance
· The main performance of then product can satisfy the requests of  GB/T 4109 《Insulated bushing for alternating voltages above 1000V》and IEC 60137《Insulated bushing for alternating voltages above 1000V》.

· Rated insulation level and partial discharge level

Highest voltage Um(kV)Rated insulation levelPartial discharge level
Power frequency withstand voltage (kV)Lightning impulse withstand voltage (kV)Partial discharge test voltage (kV)Partial discharge(pC)
12427512/7.310/5
245012524/1510/5
40.59520040.5/2510/5

· Dielectric loss factor
Dielectric loss factor is not greater than 0.005 under 10kV and 1.05Um/√3kV(ambient air temperature 10~40℃).
· Temperature rising limit
The highest temperature rising of winding is not greater than 75K.
· Rated short-time thermal current is twenty-five times rated current when time keeps up 1 second.
· Minimum values of cantilever withstand load

Highest voltage
Um (kV)

Rated current (A)

≤800

1000~1600

2000~2500

≥3150

12

1000

1250

2000

3150

24

1000

1250

2000

3150

40.5

1000

1250

2000

3150

■ Acceptance and maintenance
Every high voltage wall bushing has passed the tests including power frequency withstand voltage,partial discharge,dielectric loss factor,terminal withstand voltage before leaving the factory. We follow up GB/T4109 《Insulated bushing for alternating voltages above 1000V》and IEC 60137《Insulated bushing for alternating voltages above 1000V》when the products are handed over. In generally,the products need no maintenance basically.It is enough to check the primary winding capacity and dielectric loss factor every 2~3 years.

■ Transportation and installation
· The products should be packed by shockproof material when they are transported.
· Pay attention to the silicon rubber umbrellas when the products are suspended.
· Documents:certificate,test report,product manual.They should be put into packing box with the products.
· Please earth reliably the terminal of the products after installing.

■ Notice for order
You should specify the following parameters at least when ordering:
· Electric parameters:Highest voltage,rated current,rated short-time thermal current,creepage distance.
· Environment condition:ambient air temperature,altitude,pollution class,installation way.
· You should offer correct parameters according to the requests of current transformer if you want to append wall bushing type current transformer,at then same time you should illuminate discerption type or integrated type.

We can offer the special products too.

Figuration dimension(unit:mm)

Type

Rated current

L

L1

Number of copper bars

Copper bars thickness

Copper bars spacing

FCRG2-12/

3150

890

420

2

10

10

4000

890

420

3

10

10

FCRG2-24/

3150

1050

450

2

10

10

4000

1050

450

3

10

10

FCRG2-40.5/

3150

1220

560

2

10

10

4000

1220

560

3

10

10

 